ATLAS 550 System Manual

Section 4, User Interface Guide

 

 

Manager > Packet Endpnts > Config > Endpnt Name on page 196).

PACKET MANAGER > PACKET ENDPNTS > PERFORMANCE > PROT

Read security: 5

Displays the layer 2 protocol for this packet endpoint. FR indicates this packet endpoint is configured for frame relay. TBOP indicates this packet endpoint is configured for Transparent Bit Oriented Protocol (TBOP). PPP indicates this packet endpoint is configured for the Point-to-Point Protocol. SDLC indicates this packet endpoint is configured for SDLC signaling.

SDLC signaling is only available using the Legacy Data Option Module (P/N 1200342L1).

PACKET MANAGER > PACKET ENDPNTS > PERFORMANCE > LINK STATS - FRAME RELAY

Write security: 3; Read security: 5

Displays layer 2 performance statistics. The statistics fields for frame relay reflect the total count since last cleared. The available statistic information is discussed below.

TX PACKETS

Total number of frame relay packets transmitted through this packet

 

endpoint, including both user data (on all PVCs) and signaling.

RX PACKETS

Total number of frame relay packets received through this packet

 

endpoint on all PVCs.

STATE CHANGES

Total number of times that frame relay signaling has gone active or

 

inactive.

SIGNALING ERRORS

Total number of signaling frames received with PVC signaling protocol

 

violations.

SIGNALING TIMEOUTS

Number of times signaling polls were not received in the time specified

 

in T391 in the PACKET ENDPTS/CONFIG menu.

ASYNC STATUS TX

Full status not transmitted during the normal full status cycle. An

 

asynchronous status message is used to quickly activate a link.

ASYNC STATUS RX

Full status not received during the normal full status cycle. An

 

asynchronous status message is used to quickly activate a link.

FULL STATUS TX

Number of full status polls transmitted by this packet endpoint.

FULL STATUS RX

Number of full status polls received by this packet endpoint.

LINK INTEGRITY

Number of link integrity polls transmitted by this packet endpoint.

STATUS TX

 

LINK INTEGRITY

Number of link integrity polls received by this packet endpoint.

STATUS RX

 

CLEAR COUNTERS

Clears all values in this submenu.

61200305L1-1F

© 2002 ADTRAN, Inc.

193

Page 193
Image 193