Section 7, System Event Logging ATLAS 550 System Manual
382 © 2002 ADTRAN, Inc. 61200305L1-1F
Cold NORMAL System cold start2
Firmware update completed INFO Flash download successful
Module Found INFO Module found
SNMP Authentication Failure INFO SNMP authentication failure3
1 Three consecutive logins were attempted and failed.
2 Generated five seconds after the completion of system initialization.
3 Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP communities
list but with a community name that does not match the community name defined in the SNMP communities list.
Table 2. Switchboard Events
Console Log String Category Event
<number> rejected: No such number WARNING Call rejected1
1 No such number in dial plan.
<number> rejected: Outgoing reject list NORMAL Call rejected2
2 Number is on outgoing reject list.
<number> rejected: Busy NORMAL Call rejected3
3 All endpoints busy.
<number> accepted: <slot> <port> NORMAL Call successfully routed
Table 3. Nx 56/64 Events
Console Log String Category Event
Nx 56/64 511 Test Pattern Active WARNING 511 Test Pattern Activated
Nx 56/64 511 Test Pattern Cleared WARNING 511 Test Pattern Deactivated
Nx 56/64 Bilateral Loopback Active WARNING Bilateral Loopback Activated
Nx 56/64 Bilateral Loopback Cleared WARNING Bilateral Loopback Deactivated
Nx 56/64 Excessive Zeros Alarm WARNING Excessive Zeros from DTE
Nx 56/64 Excessive Zeros Alarm Cleared WARNING Excessive Zeros condition cleared
Nx 56/64 Clock Slip Alarm Active MAJOR Clock Slip Alarm Active
Nx 56/64 Clock Slip Alarm Cleared MAJOR Clock Slip Alarm Cleared
Nx 56/64 External Clock Alarm Active MAJOR External Clock Alarm
Table 1. System Controller Events (Continued)
Console Log String Category Event