Section 4, User Interface Guide

ATLAS 550 System Manual

 

 

DLCI

Read security: 5

Displays the local address for each PVC as assigned by the carrier.

TEST

Write security: 3; Read security: 5

Displays the test mode for the PVC.

START

Write security: 3; Read security: 5

The fixed duration that Test is not running and the DLCI is not configured for continuous in-band delay measurement. To change this option, set DIAGNOSTIC MODE to IN-BANDDELAY MEASUREMENT (also see Packet Manager > Packet Endpnts > Config > Config - SDLC, In-band Delay Measurement option).

CONTDLY

Write security: 3; Read security: 5

The fixed duration TEST is not running and the DLCI is configured for continuous in-band delay measurement. The following RESULTS menu accumulates these measurements.

STOP

Write security: 3; Read security: 5

The fixed duration TEST is running. The following DURATION field shows the time remaining in the current test.

DURATION

Read security: 5

Shows the duration in seconds for the fixed-duration test.

RESULTS [MN/AV/MX DLY]

Read security: 5

Displays the minimum, average, and maximum delay for the delay-measurement test. To display the additional test results, place the cursor over this field and press <Enter > on the keyboard. The displayed times are in milliseconds.

ECHO PKT TX

Read security: 5

Displays the total number of test packets that have been transmitted.

ECHO PKT RX

Read security: 5

Displays the total number of test packets that have been received.

206

© 2002 ADTRAN, Inc.

61200305L1-1F

Page 206
Image 206
ADTRAN 1200305L1 Displays the test mode for the PVC, Shows the duration in seconds for the fixed-duration test