ATLAS 550 System Manual Section 4, User Interface Guide
61200305L1-1F © 2002 ADTRAN, Inc. 243
DEDICATED MAPS (DUAL NX 56/64 MODULE)DEDICATED MAPS (V35NX) > CREATE/EDIT MAPS > CONNECTS
Write security: 3; Read security: 5
Enters the dedicated map connections. Press <Enter> to activate the submenus.
DEDICATED MAPS (V35NX) > CREATE/EDIT MAPS > CONNECTS > TO/FROM CONFIG
Write security: 3; Read security: 5
Specifies the configuration for the FROM connection. The following selections may apply to the Dual Nx
56/64 Option Module, depending on the application:
SIGNALING METHOD
Write security: 3; Read security: 5
Defines the mode of operation of the selected voice port. The signaling on the T1 mapped to this
voice port must match. The options include LOOPSTART, GROUNDSTART, and DPT.
ANSWER SUPERVISION
Write security: 3; Read security: 5
Configures answer supervision for the appropriate voice port. Answer supervision (when the far end
answers the call) is indicated by using reverse battery polarity. This is valid for an outbound call
only. When the FXO originates a call, it looks for reverse polarity on the 2W interface. If reverse
battery is detected, LSAS is transmitted on the T1. This requires Loopstart interfaces to be polarity
dependent.
Keep this option disabled unless you are certain you need LSAS capability.
DS0 SELECTION
Write security: 3; Read security: 5
Defines DS0s for an Nx port. Use this field to define the DS0s for this connection. This field only
applies to Nx-to-Nx or Nx-to-Pkt Endpt connections.
DS0 RATE
Write security: 3; Read security: 5
Sets the DS0 rate to either 56 or 64 kbps.