Table 29. HSSI/V.35 Connection Pinout (Continued)

 

 

 

 

 

22

47

O

V.35

RD - Receive Data

 

 

 

 

 

23

O

V.35

CTS - Clear to Send

 

 

 

 

 

48

I

V.35

Ground/Present

 

 

 

 

24

49

O

TM - Test Mode

 

 

 

 

25

50

 

SG - Signal Ground

 

 

 

 

 

 

Table 30. T1 Network Connection Pinout

PIN

 

NAME

DESCRIPTION

 

 

 

 

1

R1

RXDATA-RING

Receive data from the network

 

 

 

 

2

T1

RXDATA-TIP

Receive data from the network

 

 

 

 

3

UNUSED

 

 

 

 

4

R

TXDATA-RING

Send data towards the network

 

 

 

 

5

T

TXDATA-TIP

Send data towards the network

 

 

 

 

6,7,8

UNUSED

 

 

 

 

Legacy Data Option Module (P/N 1200342L1)

The Legacy Data Option Module provides four EIA-232 or V.35 interfaces (or any combination up to four) for sync or async packet data applications. Table 31 gives the pinouts for both the EIA-232 and V.35 connections.

Connector Types

EIA-232 and V.35

 

 

Table 31. EIA-232 and V.35 Connection Pinouts

 

 

 

 

EIA-232 PIN

V.35 PIN

CCITT/V.24 PIN

DESCRIPTION

 

 

 

 

-

A

101

Protective ground (PG)

 

 

 

 

7

B

102

Signal ground (SG)

 

 

 

 

4

C

105

Request to send (RTS) from DTE

 

 

 

 

5

D

106

Clear to send (CTS) to DTE

 

 

 

 

6

E

107

Data set ready (DSR) to DTE

 

 

 

 

8

F

109

Received line signal detector (DCD) to

 

 

 

DTE

 

 

 

 

20

H

108/2

Data terminal ready (DTR) from DTE

 

 

 

 

61200305L1-1F

© 2002 ADTRAN, Inc.