MODULES (DBU) > BRI TEST

Write security: 4; Read security: 5

The following options initiate tests and display test results.

MODULES (DBU) > BRI TEST > LOCAL LOOPBACK

Write security: 3; Read security: 5

Activates a local loopback of the Basic Rate ISDN (BRI) U interface toward the network. The following options are available:

NONE

No active loopback

LOOPBACK B1

Loops the first B channel of the interface

LOOPBACK B2

Loops the second B channel of the interface

LOOPBACK B1 & B2

Loops both B channels of the interface

LOOPBACK ALL

Loops the entire physical interface (2B + D)

MODULES MENU (DUAL/QUAD T1/PRI OPTION MODULES)

This section provides detailed information on the MODULES menu and submenus for the Dual/Quad T1/PRI Option Modules. The ATLAS 550 system controller automatically detects the presence of the Dual/Quad T1/PRI Option Modules when they are installed in the system (Dual is listed as T1/PRI-2and the Quad is listed as T1/PRI-4). All menus detailed in this section that apply to both modules are listed as T1/PRI-2/4. To see the menus for the Dual/Quad T1/PRI Option Modules via the terminal menu, use the arrow keys to scroll to the MODULES menu and press <Enter> to access the module choices. Refer to the Dual/Quad T1/PRI Option Modules Quick Start Guide for a menu tree containing a complete listing of menus.

MODULES (T1/PRI-2/4) > INFO

Read security: 5

Displays general information about the T1/PRI Network Interface Module as follows:

MODULES (T1/PRI-2/4) > INFO > PART NUMBER

Read security: 5

Displays the part number of the T1/PRI Network Interface Module.

MODULES (T1/PRI-2/4) > INFO > SERIAL NUMBER

Read security: 5

Displays the module’s serial number.

MODULES (T1/PRI-2/4) > INFO > ASSEMBLY REVISION

Read security: 5

Displays the assembly revision of the module.

61200305L1-1F

© 2002 ADTRAN, Inc.