ATLAS 550 System Manual

Section 2, Engineering Guidelines

 

 

1.EQUIPMENT DIMENSIONS

The ATLAS 550 base unit is 17.08” W, 11.67” D, and 3.47” H. All other equipment (option modules) fit inside the base unit.

2.POWER REQUIREMENTS

The ATLAS 550 has a maximum power consumption of 60 W and a maximum current draw of 2 A (AC System) or 5 A (DC System) regardless of the configuration of option modules installed in the base unit.

3.REVIEWING THE FRONT PANEL DESIGN

The front panel contains the Alarm Cut-off (ACO) switch, the CRAFT port, and the controller and module status LEDs. The LEDs provide visual information about the ATLAS 550 base unit and any option module that may be installed. Figure 1 identifies the ACO switch, the CRAFT port, and the LEDs.

Network Module

Option Module

Status LEDs

Slot Numbers

 

 

 

 

 

 

 

ATLAS 550

 

 

1

2

1

2

3

4

POWER

 

OK

OK

STATUS

 

 

 

SYSTEM

 

TEST

TEST

ONLINE

 

 

 

ETHERNET

 

ERROR

ERROR

TEST

 

 

 

REMOTE

 

ALARM

ALARM

 

 

MODULES

 

 

 

 

NETWORK

 

 

 

 

 

 

CRAFT

 

 

 

 

 

 

ACO

 

 

 

 

 

 

Controller

Alarm

CRAFT

 

 

Module Status LEDs

 

Status

Cut-off

Port

 

 

 

 

 

LEDs

Switch

 

 

 

 

 

 

Figure 1. ATLAS 550 Front Panel Layout

ACO Switch

The ACO switch deactivates (clears) the Alarm Relay, located on the rear panel of the ATLAS 550, after an alarm condition has occurred. If an alarm condition is corrected and then reoccurs, the Alarm Relay will re-energize.

61200305L1-1F

© 2002 ADTRAN, Inc.

25

Page 25
Image 25
ADTRAN 1200305L1 system manual Equipment Dimensions, Power Requirements, Reviewing the Front Panel Design, ACO Switch