ATLAS 550 System Manual Section 4, User Interface Guide
61200305L1-1F © 2002 ADTRAN, Inc. 213
TX LI ONLY
Read security: 5
The number of PVC-signaling, link integrity only frames transmitted.
ASYNC STATUS
Read security: 5
The number of single PVC status frames received.
DISCARD FRAME
Read security: 5
The number of frames discarded by the IQ unit.
ABORTS
Read security: 5
The number of frames received without proper flag termination.
CRC ERROR
Read security: 5
The number of frames received with CRC errors.
OCTET ALIGN
Read security: 5
The number of frames received with a bit count not divisible by eight.
LENGTH ERROR
Read security: 5
The number of frames received that are less than 5 bytes or greater than 4500 bytes.
EA VIOLATION
Read security: 5
The number of frames received with errors in the EA field of the frame relay header.
INACTIVE DLCI
Read security: 5
The number of frames received while the PVC is in the inactive state.
INVALID DLCI
Read security: 5
The number of frames received with a DLCI value less than 16 or greater than 1007, not including
PVC signaling frames.