Section 4, User Interface Guide ATLAS 550 System Manual
200 © 2002 ADTRAN, Inc. 61200305L1-1F
PACKET MANAGER > PACKET ENDPNTS > CONFIG > CONFIG - SDLC
Write security: 3; Read security: 5
Contains the configuration parameters for the SDLC packet endpoints.
MAX CONFIG
Write security: 3; Read security: 5
This value is the number of unanswered configuration requests that should be transmitted before
giving up on negotiation. The default value is 10.
MAX TIMER
Write security: 3; Read security: 5
This value is the number of seconds to wait between unanswered configuration requests. The default
value is 2 seconds.
MAX FAILURE
Write security: 3; Read security: 5
Due to the nature of PPP, configuration options may not be agreed upon between two PPP peers. This
value is the number of configuration-NAKs that should occur before an option is
configuration-rejected. This allows a connection to succeed that might otherwise fail. The default
value is 5.
KEEPALIVE
Write security: 3; Read security: 5
Configures the ATLAS 550 to send keepalive frames on PPP connections that are not currently in use
for data.
Extreme caution should be used when changing the following parameters from their
default state.
POLL RESPONSE TIMEOUT
Write security: 3; Read security: 5
Sets the number of seconds the ATLAS 550 waits for a poll response before marking the poll as
unanswered.
MINIMUM POLL TIMER
Write security: 3; Read security: 5
Sets the number of seconds the ATLAS 550 waits between polls. The timer is started when the first
poll is sent and will be restarted when the next poll is sent.