ATLAS 550 System Manual Section 4, User Interface Guide
61200305L1-1F © 2002 ADTRAN, Inc. 133
MODULES (V35NX-2) > PLL/FIFO > PLL/FIFO
Read security: 5
Displays the state of the PLL and FIFO systems.
MODULES (V35NX-2) > CONFIGURATION
Write security: 3; Read security: 5
All of the following configurable parameters apply to the individual V.35 ports.
MODULES (V35NX-2) > CONFIGURATION > PRT
Read security: 5
Displays the port number. There are 2 available interfaces on the Dual Nx56/64 Option Module.
MODULES (V35NX-2) > CONFIGURATION > PORT NAME
Write security: 3; Read security: 5
Accepts any alpha-numeric name up to 17 characters long, to uniquely identify each port on the Dual
Nx56/64 Option Module.
MODULES (V35NX-2) > CONFIGURATION > CLK +/-
Write security: 3; Read security: 5
Controls the clock used by the ATLAS 550 to accept the transmit (TX) data from the DTE. This is usually
set to NORMAL. If the interface cable is long, causing a phase shift in the data, the clock can be set to
INVERTED. This switches the phase of the clock, which compensates for a long cable.
MODULES (V35NX-2) > CONFIGURATION > DATA
Write security: 3; Read security: 5
Controls the inverting of the DTE data. This inversion can be useful when operating with a high-level data
link control (HDLC) protocol (often used as a means to ensure 1s density). Select either NORMAL or
INVERTED. Data inversion configuration must match at both ends of the circuit.
MODULES (V35NX-2) > CONFIGURATION > CTS
Write security: 3; Read security: 5
Determines the behavior of the Clear To Send (CTS) signal. If set to NORMAL, CTS will follow the value of
Request To Send (RTS). If set to FORCED ON, CTS will always be asserted.
LOCK PLL is locked (This is required to transfer data.)
RXE Receive data FIFO empty.
RXF Receive data FIFO full.
TXE Transmit data FIFO empty.
TXF Transmit data FIFO full.