Section 4, User Interface Guide

ATLAS 550 System Manual

 

 

SYSTEM UTILITY

Use the SYSTEM UTILITY menu to view and set the system parameters shown in Figure 6.

Figure 6. System Utility Menu

SYSTEM UTILITY > UPDATE FIRMWARE

Write security: 1; Read security: 5

Updates firmware when ATLAS 550 enhancements are released. Two transfer methods are available for use in updating any modules that contain Flash memory—including the ATLAS 550 system controller. The first transfer method uses the ATLAS 550 serial CRAFT or CONTROL IN (Chain) port of the system controller and XMODEM protocol. The second transfer method uses the ATLAS 550 built-in ETHERNET port of the system controller and Trivial File Transfer Protocol (TFTP). For more details on updating firmware, please refer to DLP-006and DLP-007.

SYSTEM UTILITY > UPDATE FIRMWARE > MODULE SLOT

Write security: 1; Read security: 5

Displays the slot you selected for firmware updating. When this option first appears, NONE SELECTED displays. When you move the cursor to this field and press <Enter>, a dialog box opens, allowing you to select SLOT 0 (ATLAS 550 system controller), NTWK 1 or 2 (if an upgradeable network module is installed), SLOT 1 through SLOT 4 (if an upgradeable module is installed), RSRC 1 through 4 (if an upgradeable resource module is installed), or ALL MODULES OF A TYPE.

SYSTEM UTILITY > UPDATE FIRMWARE > MODULE TYPE

Write security: 1; Read security: 5

Reflects the module type selected in MODULE SLOT. The selections only include upgradeable modules.

92

© 2002 ADTRAN, Inc.

61200305L1-1F

Page 92
Image 92
ADTRAN 1200305L1 system manual System Utility