61200305L1-1F © 2002 ADTRAN, Inc. 323
SETTING IP PARAMETERS FOR THE ATLAS 550
Introduction
If the ATLAS 550 is connected to an IP network for Telnet, TFTP, or SNMP management, several IP
parameters must be set for the unit to communicate with the network. These parameters are described in
this DLP along with the procedures for setting them.
Prerequisite Procedures
This procedure assumes that the ATLAS 550 unit is connected to an IP network and is powered up.
Tools and Materials Required
Data cable to connect to either a VT100 terminal or a PC configured as a VT100 terminal
VT100 terminal or PC configured as a VT100 terminal
Please see your Network Administrator for the proper assignment of the following
parameters: IP ADDRESS, SUBNET MASK, and DEFAULT GATEWAY.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling
modules, wear an antistatic discharge wrist strap to prevent damage to electronic
components. Place modules in antistatic packing material when transporting or storing.
When working on modules, always place them on an approved antistatic mat that is
electrically grounded.