ATLAS 550 System Manual Section 4, User Interface Guide
61200305L1-1F © 2002 ADTRAN, Inc. 263
DIAL PLAN > GLOBAL PARAM > END OF NUMBER TIMEOUT
Write security: 3; Read security: 5
Sets the length of time ATLAS 550 waits before assuming the outgoing dialed number is complete. The
default value is six seconds. This timeout will only be invoked if the dialed number does not match one of
the patterns set in the NUMBER COMPLETE TEMPLATE menu (see Nbr Complete Templates below).
DIAL PLAN > GLOBAL PARAM > COUNTRY CODE
Write security: 3; Read security: 5
The country code. Enter your international country code using only digits. For the United States, enter 1.
DIAL PLAN > GLOBAL PARAM > AREA OR CITY CODE
Write security: 3; Read security: 5
The local area code. Use for sending caller ID to the network.
DIAL PLAN > GLOBAL PARAM > NBR COMPLETE TEMPLATES
Write security: 3; Read security: 5
Sets completed number patterns for outgoing calls so that ATLAS 550 recognizes when the phone number
is complete. Fields include the index number (#) and PATTERN. For example, a local number will be 7
digits long while a long distance (1+ area code + number) will be 11 digits long. The ATLAS 550 defaults
cover almost any installation, and these templates should not require any additional user input – except for
unusual circumstances. The template allows the use of the following wildcard inputs to define numbers:
DIAL PLAN > GLOBAL PARAM > NUMBER TYPE TEMPLATES
Write security: 3; Read security: 5
Sets call type patterns. ISDN interfaces require that a number type be sent over the D channel when a call
is sent or received. A normal RBS trunk does not send a type designator, but uses prefixes instead. For
example, “1 +” prefix is a national long distance call type while a “011 +” prefix is an international long
distance call type. These templates form a table to permit ATLAS 550 to translate the RBS prefix into a
call type for ISDN and vice-versa.
DIAL PLAN > GLOBAL PARAM > NUMBER TYPE TEMPLATES > #
Write security: 3; Read security: 5
Denotes an entry number. The maximum number of entries is 50. Press < I > to insert a new entry and
< D > to delete any entry.
X = Any single digit
N = Any single digit 2 through 9
911 = This specific number
[1,2,3...] = A single digit in this group
The ATLAS 550 default templates should cover all applications and should not need to be
added to by the user except for very rare circumstances.