IDLE
RING GROUND OFF HOOK REVERSE BATTERY RINGING TIP-OPEN
UNKNOWN
INACTIVE AVAILABLE NOT AVAILABLE DISABLED TEST
61200305L1-1F

ATLAS 550 System Manual

Section 4, User Interface Guide

MODULES (FXO-4/8) > INFO > ASSEMBLY REVISION

Read security: 5

Displays the assembly revision of the module.

MODULES (FXO-4/8) > INFO > FIRMWARE REVISION

Read security: 5

Displays the current firmware revision of the selected module.

MODULES (FXO-4/8) > INFO > PROCESSOR ID

Read security: 5

Displays the processor ID of the selected module.

MODULES (FXO-4/8) > STATUS

Read security: 5

Displays the status of each of the FXO ports.

MODULES (FXO-4/8) > STATUS > PRT

Read security: 5

Indicates the port number. There are 4 available interfaces on the Quad FXO Option Module and 8 on the Octal FXO Option Module.

MODULES (FXO-4/8) > STATUS > STATUS

Read security: 5

Displays the call status of each voice port. This field may display the following:

The FXO port is in an idle state for LS configurations, and tip is grounded in GS configurations.

The FXO port has detected ring ground.

The FXO port has detected an off hook condition (loop current flowing). The FXO port has reversed T/R polarity.

The FXO port is detecting ringing condition on the interface.

The FXO port tip conductor is high impedance. This is an idle condition for GS trunks.

No information about the FXO port is available.

The port is preconfigured, but the FXO module is not present. The FXO port is present and available for use.

The FXO port is present, but not available for use.

The FXO module is present, but the port is not mapped.

This generic FXO port test indicator is used when multiple tests are being run or the test is not a 2W test.

© 2002 ADTRAN, Inc.

155

Page 155
Image 155
ADTRAN 1200305L1 system manual Modules FXO-4/8 Status PRT, Displays the status of each of the FXO ports