Section 4, User Interface Guide ATLAS 550 System Manual
90 © 2002 ADTRAN, Inc. 61200305L1-1F
SYSTEM CONFIG > BONDING CONFIG > TXFA TIMER
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to detect the BONDING frame pattern when a call is
connected before deciding the BONDING call has failed. When interoperating with other manufacturers'
BONDING equipment, it may be necessary to change this time so that it matches TXADD01.
SYSTEM CONFIG > BONDING CONFIG > TXADD01 TIMER
Write security: 3; Read security: 5
Specifies the length of time both endpoints wait for additional calls to be connected at the end of
negotiation before deciding that the BONDING call has failed. The factory default setting is sufficient for
most calls to connect, although when dialing overseas it may be necessary to lengthen this timer to allow
for slower call routing.
SYSTEM CONFIG > BONDING CONFIG > TXDEQ TIMER
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to equalize the network delay between the bearer
channels (B channels) before deciding the BONDING call has failed.
SYSTEM CONFIG > BONDING CONFIG > TANULL TIMER
Write security: 3; Read security: 5
Specifies the length of time the answering endpoint attempts to detect the BONDING negotiation pattern
from the originating endpoint before deciding the BONDING call has failed. It may be necessary to
shorten this timer if the DTE equipment using the BONDING module also has timer constraints for
completing non-BONDING parameter negotiation.
SYSTEM CONFIG > BONDING CONFIG > TCID TIMER
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to negotiate an agreeable value for bearer channels (B
channels) and channel capacities before deciding the BONDING call has failed.
SYSTEM CONFIG > BONDING CONFIG > CALL STAGGER
Write security: 3; Read security: 5
Specifies the amount of delay between placing calls for outgoing BONDING sessions. The following call
stagger values are available: NO STAGGER, 500 MS, 1 SEC, and 2 SEC
SYSTEM CONFIG > ALARM RELAY RESET
Write security: 3; Read security: 5
Clears the Alarm Relay located on the rear panel of the ATLAS 550. Activating the software Alarm Relay
Reset functions the same as manually pressing the ACO switch located on the ATLAS 550 front panel.