Section 4, User Interface Guide

ATLAS 550 System Manual

 

 

Controller and the voice port if the port is configured in the DIAL PLAN. The bit pattern is formatted ESF RBS.

MODULES (FXS-4/8) > STATUS > TX ABCD

Read security: 5

Transmit Signaling bits have local significance only, and represent signaling between the ATLAS 550 Controller and the voice port if the port is configured in the DIAL PLAN. The bit pattern is formatted ESF RBS.

MODULES (FXS-4/8) > TEST

Write security: 4; Read security: 5

These options initiate different types of tests and display test results.

MODULES (FXS-4/8) > TEST > PORT

Write security: 5; Read security: 5

Displays the operating port. There are 4 available interfaces on the Quad FXS Option Module and 8 on the Octal FXS Option Module.

MODULES (FXS-4/8) > TEST > TEST 2W

Write security: 4; Read security: 5

Activates 2W (FXS) tests on a per-port basis. Options include OFF, ACTIVE, TIP OPEN, REV. BATTERY,

DISABLED, and RINGING. The 2W tests will disrupt the active call on the selected FXS port. Table 3 displays the state of the 2W conductors during each test.

Table 3. FXS 2W State Table

TEST

TIP OUTPUT

RING OUTPUT

 

 

 

Off

No test active

No test active

 

 

 

Active

Ground

Supervision voltage

 

 

 

Tip Open

High impedance

Supervision voltage

 

 

 

Rev. Battery

Supervision voltage

Ground

 

 

 

Disabled*

High impedance

High impedance

 

 

 

Ringing

Ringing voltage

Ringing voltage

 

 

 

* Disables the output of the FXS port; it does not disable the test.

152

© 2002 ADTRAN, Inc.

61200305L1-1F

Page 152
Image 152
ADTRAN 1200305L1 system manual Modules FXS-4/8 Status TX Abcd, Modules FXS-4/8 Test Port, Modules FXS-4/8 Test Test 2W