Section 4, User Interface Guide ATLAS 550 System Manual
122 © 2002 ADTRAN, Inc. 61200305L1-1F
MODULES (DBU) > BRI CHANNEL STATUS
Read security: 5
Displays the status of the individual bearer (B) channels on the Basic Rate ISDN (BRI) interface.
MODULES (DBU) > BRI CHANNEL STATUS > PRT
Read security: 5
Indicates the port number.
MODULES (DBU) > BRI CHANNEL STATUS > CHA
Read security: 5
(Channel) Displays the status of individual channels. The following symbols may display:
MODULES (DBU) > PERFORMANCE CURRENT
Write security: 3; Read security: 5
The performance field provides status on key performance measures for the Basic Rate ISDN (BRI)
interface. All fields (except RESET) are read-only. The monitored parameters include the following:
MODULES (DBU) > BRI CONFIGURATION
Write security: 3; Read security: 5
All of the following configurable parameters apply to the Basic Rate ISDN (BRI) interface on the BRI
DBU Network Interface Module.
MODULES (DBU) > BRI CONFIGURATION > PRT
Read security: 5
Displays the port number.
MODULES (DBU) > BRI CONFIGURATION > PORT NAME
Write security: 3; Read security: 5
Accepts any alpha-numeric name up to 16 characters long, to uniquely identify the Basic Rate ISDN (BRI)
interface on the BRI DBU Network Interface Module.
-Unallocated channel
.Inactive channel
BActive B channel
DActive D channel
PRT Displays the port number
RESET Resets the NEBE and FEBE statistics
NEBE CURRENT Near-end block errors
FEBE CURRENT Far-end block errors