Section 4, User Interface Guide ATLAS 550 System Manual
238 © 2002 ADTRAN, Inc. 61200305L1-1F
TS0 SELECTION
Write security: 3; Read security: 5
Defines TS0s for an E1 port. Use this field to define the TS0s for this connection. You can enter the
TS0s in several ways. For example, to enter TS0s one through five, enter 1-5. For TS0s one and five,
enter 1,5.
TS0 AVAILABLE
Write security: 3; Read security: 5
Indicates which TS0s of the E1 are assigned. TS0 assignment is based on the following items:
DIGIT 0-9 This TS0 is available. The digit that displays in this field represents the
last digit of the TS0 number.
*This TS0 has been requested for this connection, but the TS0 is not yet
activated for this port.
!This TS0 is used by this port in this connection and is currently
activated.
SThis TS0 is used in the switched DIAL PLAN.
SThis TS0 is used in the switched DIAL PLANand conflicts with this
connection.
NThis TS0 is already used in this DEDICATED MAP.
NThis TS0 is already used in this DEDICATED MAP and conflicts with this
connection.
TS0 RATE
Write security: 3; Read security: 5
Sets the TS0 rate to either 56 or 64 kbps. This field is only valid for E1 ports mapped to a PKT
ENDPNT.
E1 TROUBLE CODE SERVICE
Write security: 3; Read security: 5
Sets known values in the signaling bits and the data field for outgoing TS0s which are
cross-connected to a E1 port experiencing alarms.
The trunk conditioning process consists of a 2.5 second transmission (indicating call termination),
followed by a continuous transmission signaling the final condition as chosen by the user. Set the E1
TROUBLE CODE SERVICE field to OFF or VOICE.
T1 TROUBLE CODE VALUE
Write security: 3; Read security: 5
Displays the Hex value of the 2.5 second pre-alarm transmission.