ATLAS 550 System Manual Section 4, User Interface Guide
61200305L1-1F © 2002 ADTRAN, Inc. 163
MODULES (LEGACY-4) > INFO > PROCESSOR ID
Read security: 5

Displays the processor ID of the selected module.

MODULES (LEGACY-4) > SIGNAL STATUS
Read security: 5

Shows the status of key DTE interface signals. An asterisk (*) indicates the presence of a signal and a

hyphen (-) indicates no signal present.

MODULES (LEGACY-4) > SIGNAL STATUS > PORT
Read security: 5
Displays the operating port number. There are four available ports on the Legacy Data Option Module.
MODULES (LEGACY-4) > SIGNAL STATUS > DTE SIGNALS
Read security: 5

The following signals are monitored (these options are read-only):

MODULES (LEGACY-4) > PORT STATS
Write security: 5; Read security: 5

Shows statistics for each port of the Legacy Data Option Module including a frame count of transmitted

and received frames, errors, and async/sync statistics.

MODULES (LEGACY-4) > PORT STATS > PRT
Read security: 5
Displays the operating port number. There are four available ports on the Legacy Data Option Module.
MODULES (LEGACY-4) > PORT STATS > CLR
Write security: 3; Read security: 5

Clears all statistics for the selected port of the Legacy Data Option Module.

MODULES (LEGACY-4) > PORT STATS > FR IN
Read security: 5

(Frames In) Displays the total received frames since the last reset.

MODULES (LEGACY-4) > PORT STATS > FR OUT
Read security: 5

(Frames Out) Displays the total transmitted frames since the last reset.

DTR Data terminal ready from DTE DCD Data carrier detect to DTE

DSR Data set ready to DTE CTS Clear to send to DTE

RTS Request to send from DTE