Section 4, User Interface Guide

ATLAS 550 System Manual

 

 

MODULES (USSI-2) > ALARM STATUS > ALARMS

Read security: 5

Displays an alarm condition on the ATLAS 550 unit.

SLIP

A rate mismatch exists between the DTE clock and the network-side

 

clock (as set by DS0 assignment).

PLL

The USSI port is not able to lock onto the clock provided by the

 

network interface.

ZERO

The DTE is sending an excessive number of consecutive zeroes to the

 

network interface.

NO EXT CLK

The DTE is not providing an external transmit clock. This alarm

 

displays only if the USSI port is configured to get its transmit clock

 

from the DTE.

PKT EP ALM

A packet endpoint has detected missing or incorrect framing.

MODULES (USSI-2) > DTE STATUS

Read security: 5

Shows the status of key DTE interface signals. An asterisk (*) indicates the presence of a signal and a hyphen (-) indicates no signal present.

MODULES (USSI-2) > DTE STATUS > PRT

Read security: 5

Operating port number. There are 2 available interfaces on the Dual USSI Option Module.

MODULES (USSI-2) > DTE STATUS > DTE STATUS

The following signals are monitored (these options are read-only):

RTS

Request to send from DTE.

CTS

Clear to send to DTE.

DTR

Data terminal ready from DTE.

DSR

Data set ready to DTE.

DCD

Data carrier detect to DTE.

RI

Ring indicate to DTE.

TD

Transmit data from the DTE.

RD

Receive data toward the DTE.

EC

External clock present.

MODULES (USSI-2) > DATA RATE

Read security: 5

Displays the data rate at which each USSI port is currently operating. A port’s data rate is determined by the number of DS0s assigned to it and the rate per DS0 associated with the active maps.

138

© 2002 ADTRAN, Inc.

61200305L1-1F

Page 138
Image 138