Chapter 8. Packet Manager

OFF

Use when the remote device does not support frame relay signaling.

AUTO

Detects the role of the device on the other end of the circuit and auto- matically sets this packet endpoint to the appropriate value.

BOTH

Operates in NNI mode.

NETWORK

Acts as the network side of the UNI interface.

USER

Acts as the user side of the UNI interface.

SIGNALING TYPE

Controls the frame relay signaling type that operates on this packet end- point.

AUTO

Detects the signaling type of the device on the other end of the circuit and sets this packet endpoint to the same signaling type.

ANNEX A

Transmits and responds to ITU-T Q.933-A standards.

ANNEX D

Transmits and responds to ANSI T1.617-D standards.

LMI

Transmits and responds to Group of Four specifications.

USER POLL TIMER (T391)

Sets the polling interval to the network in seconds.

USER POLLS PER STATUS (N391)

Controls how many link integrity polls occur between full status polls.

USER BAD EVENT THRESHOLD (N392)

Sets the number of bad polling events that will cause the link to be declared down in N393 Polls.

USER EVENT WINDOW SIZE (N393)

Defines the number of poll events in each monitored window.

If the number of polls reaches N392 in any N393 period, the link will be declared down. When N393 good polls are received, the link will be declared active again.

NET POLL RESPONSE TIMEOUT (T392)

Determines how long this packet endpoint will wait without receiving a poll before declaring the poll bad.

61200305L1-1

ATLAS 550 User Manual

8-7

Page 101
Image 101
ADTRAN 550 user manual Operates in NNI mode