Chapter 10. Dedicated Maps

Table 10-1 describes the options for T1 TRUNK CONDITIONING SERVICE.

 

 

Table 10-1. T1 Trunk Conditioning Service Options

 

 

 

Option

 

Description

 

 

T1 Trunk Conditioning State

Defines the final fault signaling state as follows:

 

 

IDLE is used for one-way trunks; that is, for outgoing or incoming

 

 

calls, but not both.

 

 

SEIZED is used for two-way trunks. It prevents the PBX from

 

 

attempting to use a failed trunk for an outgoing call.

 

 

This option is not included for CUSTOM.

 

 

T1 Fault Signaling (AB/AB)

Defines to the ATLAS 550 the signaling bits being used on the trunk.

 

 

Fault signaling is only visible when RBS is turned on.

 

 

 

T1 Trouble Code Value

 

Defines to the ATLAS 550 the value to set in the data field for

 

 

outgoing DS0s when a trouble condition exists.

 

 

 

TO CONFIG

Write security: 3; Read security: 5

 

Specifies the configuration for the TO connection. The selections that dis-

 

play in this field are based on the type of module selected in the TO SLOT

 

option. See From Config on page 10-4 for a description of these settings.

SIG

Write security: 3; Read security: 5

 

(Signaling) Defines whether the connection has active RBS. Where RBS is

 

not an option, the ATLAS 550 automatically assigns the correct setting. For

 

example, a T1-to-Nx connection is set to Off.

 

RBS

Preserves the signaling bits between the connections.

 

OFF

Ignores signaling bits.

ACTIVATE TIME

Write security: 3; Read security: 5

 

Sets the time when the map becomes active if you have selected AUTO in the

 

ACTIVATE MAP field (see Activate Map on page 10-2). Enter this time in

 

hh:mm:ss 24-hour format.

ENBL DAY

Write security: 3; Read security: 5

 

Specifies which days of the week the map is active.