ADTRAN 550 user manual Current ES Thrsh

Models: 550

1 262
Download 262 pages 6.71 Kb
Page 74
Image 74

Chapter 6. System Control Terminal Menus

the STATION TYPE as T-WATCH MGMT and append the COMMUNITY NAME with

“.ADLP ADDRESS.” Within the SNMP trap packet, this field is automati- cally updated before it is sent to the management station.

DS1 CURRENT Write security: 2; Read security: 5

PERFDefines performance threshold values for DS1 Line and Path statistics

THRESHOLDS recorded in a 15-minute interval. If a statistic value exceeds its threshold value, then the corresponding Alert Trap will be sent if the alert event is armed and Alert Traps are enabled. These thresholds apply to all DS1 inter- faces in the system.

CURRENT ES THRSH

The DS1 performance monitor Threshold Value for the Current 15 minute Errored Seconds (ES) parameter. The default value is 65 for an approximate BER level of 10E-5.

CURRENT SES THRSH

The DS1 performance monitor Threshold Value for the Current 15 minute Severely Errored Seconds (SES) parameter. The default value is 10 for an approximate BER level of 10E-5.

CURRENT SEFS THRSH

The DS1 performance monitor Threshold Value for the Current 15 minute Severely Errored Framing Seconds (SEFS) parameter. The default value is 2 for an approximate BER level of 10E-5.

CURRENT UAS THRSH

The DS1 performance monitor Threshold Value for the Current 15 minute Unavailable Seconds (UAS) parameter. The default value is 10 for an approximate BER level of 10E-5.

CURRENT CSS THRSH

The DS1 performance monitor Threshold Value for the Current 15 minute Controlled Slip Seconds (CSS) parameter. The default value is 1 for an approximate BER level of 10E-5.

CURRENT PCV THRSH (D4)

The DS1 performance monitor Threshold Value for the Current 15 minute Path Code Violation (PCV) parameter, when the Line Type is Super Frame (AT&T D4 format) DS1. The default value is 72 Framing errors for an approximate BER level of 10E-5.

CURRENT PCV THRSH (ESF)

The DS1 performance monitor Threshold Value for the Current 15 minute Path Code Violations (PCV) parameter, when the Line Type is Extended Super Frame (ESF) DS1. The default value is 13,296 CRC errors for an approximate BER level of 10E-5.

CURRENT LES THRSH

The DS1 performance monitor Threshold Value for the Current 15 minute Line Errored Seconds (LES) parameter. The default value is 65 for an approximate BER level of 10E-5.

6-12

ATLAS 550 User Manual

61200305L1-1

Page 74
Image 74