Appendix C. Frame Relay Examples

 

 

 

Step 1

From PACKET MANAGER/PACKET ENDPNTS/CONFIG, create the packet end-

 

points: create a frame relay endpoint for the private frame relay link, and

 

create a TBOP link to carry the signaling between the PBXs (see Figure C-25).

 

 

 

 

 

 

 

 

Figure C-25. Menu for Creating Packet Endpoints

Step 2

From PACKET MANAGER/PACKET ENDPOINTS/CONFIG/SUBLINKS, configure

 

the sublinks.

 

All 23 voice channels can be carried by one DLCI transported on five DS0

 

channels. One DS0 and one DLCI are required for the TBOP channel carry-

 

ing the signaling between the PBXs. To ensure that both the voice and the

 

TBOP DLCIs are allocated their necessary frame relay bandwidth, set the

 

Quality-Of-Service (QOS) parameter with 64K allocated to the TBOP chan-

 

nel and 320K (5*64) allocated to the voice channels (see Figure C-26).

 

 

 

 

 

 

 

 

 

 

Figure C-26. Menu for Configuring Sublinks

Step 3

Connect the TBOP packet endpoints. Connect the TBOP data path between

 

the DS0 containing the signaling information and the private frame relay re-

 

source (see Figure C-27).

 

 

 

 

 

 

 

 

 

Figure C-27. Menu for Connecting the TBOP Endpoints

Step 4

Connect packet endpoints to the physical links. Each DS0 carrying voice from

 

the PBX must be connected to the frame relay endpoint (see Figure C-28).