Appendix A. System Event Logging

 

 

Table A-1. System Event

 

 

 

Event

Category

Console Log String

 

 

 

-24 V power supply is functioning normally

Critical

“-24 V Power Failure Cleared”

again

 

 

 

 

 

-24 V power supply is not operating properly

Critical

“-24 V Power Failure”

 

 

 

-58 V power supply is functioning normally

Critical

“-58 V Power Failure Cleared”

again

 

 

 

 

 

-58 V power supply is not operating properly

Critical

“-58 V Power Failure”

 

 

 

ACO switch pressed

Minor

ACO Switch pressed

 

 

 

Alarm detected on External Alarm Monitor

Minor

External Alarm Detected

 

 

 

ATLAS configuration file loaded into the

Critical

System Configuration Uploaded

system and activated

 

 

 

 

 

Console login failurea

Minor

Login Failure

Corrupted firmware

Critical

Firmware invalid

 

 

 

External alarm cleared

Minor

External Alarm Cleared

 

 

 

Flash download failed

Critical

Firmware update failed

 

 

 

Flash download successful

Info

Firmware update completed

 

 

 

Internal system temperature has cooled

Critical

>70 Internal Temperature Warning

below 70o C

 

Cleared

Internal system temperature has cooled

Critical

>85 Internal Temperature Warning

below 85o C

 

Cleared

Internal system temperature is greater than

Critical

>70C Internal Temperature Warning

70o C

 

 

Internal system temperature is greater than

Critical

>85C Internal Temperature Warning

85o C

 

 

Module found

Info

Module Found

 

 

 

Module removed or not responding

Warning

Module Not Responding

 

 

 

Neither the primary nor the backup are valid

Minor

Timing source changed to Internal

 

 

 

SNMP authentication failureb

Info

SNMP Authentication Failure

System cold startc

Normal

Cold

The primary source is not Backup valid

Minor

Timing source changed to Backup

 

 

 

The timing source changed to primary

Minor

Timing source changed to Primary

 

 

 

Unable to program module

Minor

Not responding to programming

 

 

 

a.Three consecutive login attempts were attempted and failed.

b.Generated if the ATLAS receives an SNMP request from an SNMP manager defined in theATLAS SNMP com- munities list but with a community name that does not match the community name defined in the SNMP commu- nities list.

c.Generated five seconds after the completion of system initialization.

A-2

ATLAS 550 User Manual

61200305L1-1

Page 204
Image 204
ADTRAN 550 user manual Table A-1. System Event, Event Category Console Log String