Chapter 11. Dial Plan
GLOBAL PARAM
END OF NUMBER TIMEOUT
AREA CODE
NBR COMPLETE TEMPLATES
NUMBER TYPE TEMPLATES
#
Sets ATLAS 550 options which apply to all switched operations, both incom- ing and outgoing calls.
Write security: 3; Read security: 5
Sets the length of time ATLAS 550 waits before assuming the outgoing dialed number is complete. The default value is six seconds. This timeout will only be invoked if the dialed number does not match one of the pat- terns set in the Number Complete Template menu (see the section, Nbr Complete Templates on page
Write security: 3; Read security: 5
The local area code. Use for sending caller ID to the Network.
Write security: 2; Read security: 5
Sets completed number patterns for outgoing calls so that ATLAS 550 recognizes when the phone number is complete. Fields include the index number (#) and PATTERN. For example, a local number will be 7 digits long while a long distance (1+ area code + number) will be 11 digits long. The ATLAS 550 defaults cover almost any installation, and these templates should not require any additional user
X = Any single digit
N= Any single digit 2 through 9
911 = This specific number
[1, 2, 3...] = A single digit in this group
Write security: 2; Read security: 5
Sets call type patterns. ISDN interfaces require that a number type be sent over the D channel when a call is sent or received. A normal RBS trunk does not send a type designator, but uses prefixes instead. For example, “1 +” prefix is a national long distance call type while a “011 +” prefix is an inter- national long distance call type. These templates form a table to permit ATLAS 550 to translate the RBS prefix into a call type for ISDN and vice- versa.
Denotes an entry number. The maximum number of entries is 50. Press I to insert a new entry and D to delete any entry.
The ATLAS 550 default templates should cover all applications and should not need to be added to by the user except for very rare circumstances.
PREFIX | Sets the prefix for the number type. Only digits 0 and 1 are allowed (MAX 6). |