Appendix E Troubleshooting

Power-up Self Test Fails

Modules seated improperly, module failure

Remove all modules and cycle power to the unit. If self test still fails, call Technical Support and report the results. If the self test now passes, re-insert modules one at a time, running the self test after installing each module. When an installed module causes the self test to fail, note it and report re- sults to Technical Support (see last page of this manual).

System Timing Source Unlocked

(Displayed on Terminal Interface, “System Status”)

Selected Timing Source is not present or clock is out of toler- ance

Verify that system timing is correctly configured for the desired clock.

Verify that the interface cable to clock source is present.

Temporarily configure the system to operate off of internal timing. Ver- ify that the system can lock to this clock.

Cannot establish Telnet session with ATLAS 550

Max Telnet sessions set to 0, IP address of ATLAS 550 does not match remote host IP address

Verify that the Ethernet connection is in place, check IP addresses pro- grammed in ATLAS 550 and in the Telnet client, verify that session time- out value is not set too low.

Verify the link is up via the Ethernet LED.