Chapter 6. System Control Terminal Menus
| The available update options vary depending on whether you |
| select SLOT 0, SLOTS 1 through 4, RESOURCE 1through 4 or |
| ALL MODULES OF A TYPE. |
MODULE SLOT |
|
Write security: 1; Read security: 5 | |
| Displays the slot you select for firmware updating. |
| When this option first appears, None Selected dis- |
| plays. When you move the cursor to this field and |
| press Enter, a dialog box opens, allowing you to |
| select SLOT 0 through SLOT 4, RESOURCE 1 |
| through 4 or ALL MODULES OF A TYPE. |
| ALL MODULES OF A TYPE is useful if several identical modules are installed |
| in the ATLAS 550. |
MODULE TYPE | Write security: 1; Read security: 5 |
| Reflects the module type selected in MODULE SLOT. This is normally a read- |
| only field; however, if you selected ALL MODULES OF A TYPE, you must |
| select a particular module type to update all modules of that type. The |
| selections only include upgradable modules. |
TRANSFER | Write security: 1; Read security: 5 |
METHOD | Lists the two transfer methods for updating firmware: XMODEM and TFTP, |
| after selecting a module slot. XMODEM transfers files by connecting to a |
| communications program that supports XMODEM uploads to the terminal |
| interface. TFTP transfers files by specifying an appropriate server address |
| and filename: |
| TFTP SERVER IP ADDRESS |
| Write security: 1; Read security: 5 |
| Configures the IP address of the TFTP Server on which the update file |
| resides. ATLAS 550 uses this field to locate the network server on which the |
| update file resides. |
| TFTP SERVER FILENAME |
| Write security: 1; Read security: 5 |
| Identifies the name of the update file to retrieve from the TFTP Server. Enter |
| the full path name and filename for the file. |
RESTART | Write security: 1; Read security: 5 |
SCHEDULE | Indicates when to restart the updated module to invoke the new code, after |
| selecting a module slot. The two options include RESTART IMMEDIATELY |
| AFTER UPDATE and RESTART AT SPECIFIED DATE AND TIME. |
| RESTART IMMEDIATELY AFTER UPDATE |
| Automatically restarts the module immediately after the update is com- |
| plete. |
ATLAS 550 User Manual |