Chapter 11. Dial Plan
SWITCH TYPE | Write security: 3; Read security: 5 |
| ||||
| Defines the type of PRI switch that the ATLAS 550 is going to emulate. If con- | |||||
| nected to another ATLAS 550, both need to be set to the same switch type. | |||||
| • | Lucent 5E | • | Northern DMS 100 | ||
| • | Nation ISDN | • | AT&T 4ESS | ||
FIRST DS0 | Write security: 3; Read security: 5 |
| ||||
| Defines to the ATLAS 550 the first DS0 for this endpoint. The ATLAS 550 | |||||
| uses DS0s, starting with this selection, to send and receive calls to and from | |||||
| the network (PSTN). The outgoing calls which are allowed or restricted | |||||
| over these DS0s are set by the OUTGOING CALL ACCEPT and REJECT NUM- | |||||
| BERS (discussed in the ATLAS 550 User Manual). | |||||
NUMBER OF DS0S | Write security: 3; Read security: 5 |
| ||||
| Specifies the number of DS0s ATLAS 550 uses for this endpoint. | |||||
STRIP MSD | Write security: 3; Read security: 5 |
| ||||
| Strips a selected quantity (choose from NONE, 1, 2, and 3) of the Most Signifi- | |||||
| cant Digits (MSD) of a dialed number prior to being forwarded out of the port. | |||||
| Example: |
|
|
| ||
| A network port could be set to accept all calls beginning with 9 (9$), and | |||||
| then with STRIP MSD set to 1, all digits would be sent toward the network | |||||
| except the leading 9. |
|
|
| ||
|
|
|
| |||
|
|
| STRIP MSD does not affect CALL ACCEPT criteria. All of the digits | |||
|
|
| (including the MSDs that are subsequently stripped) are used as | |||
|
|
| accept criterion. |
|
|
|
NETWORK SPECIFIC |
|
|
|
| ||
Write: 3; Read: 5 |
|
|
| |||
FACILITY | Enables the sending of appropriate information to the PSTN. The default | |||||
| for this option is NORMAL, and in this case no Network Specific Facility | |||||
| information element is sent. Unless one of the services listed below is sub- | |||||
| scribed to, the selection should remain set to NORMAL. | |||||
| The list below indicates services that may be subscribed to from the PSTN. | |||||
| These services require that specific information (such as a Network Specific | |||||
| Facility information element) be sent to the network during call setup. | |||||
| • | AT&T SDN |
| • | National ISDN INWATS | |
| • | AT&T Megacom 800 |
| • | Nortel Private Network | |
|
| – | AT&T Megacom |
| • | Nortel InWats |
|
| – | AT&T Accunet |
| • | Nortel OutWats |
| • | AT&T Long Distance |
| • | Nortel Foreign Exchange | |
| • | AT&T |
| • | Nortel Tie Trunk | |
| • | AT&T |
|
ATLAS 550 User Manual |