ADTRAN 550 user manual Event Logging, Syslog Setup

Models: 550

1 262
Download 262 pages 6.71 Kb
Page 76
Image 76

Chapter 6. System Control Terminal Menus

 

TOTAL LCV THRSH

 

The DS1 performance monitor Threshold Value for the Current 15 minute

 

Line Code Violations (LCV) parameter. The default value is 133,400 for an

 

approximate BER level of 10E-5.

EVENT LOGGING

Write security: 3; Read security: 5

 

Sets the system event severity level threshold for each of the ATLAS 550

 

system event types. Whenever a system event occurs, that event is logged if

 

the event’s severity level is equal to or more severe than the event type’s

 

current threshold setting. See System Event Logging on page A-1 for detailed

 

information on the system events.

SYSLOG SETUP

Write security: 3; Read security: 5

 

Configures the ATLAS 550 Syslog client for use with a Syslog server (sup-

 

plied on ADTRAN/Utility disk or available on most UNIX platforms).

TRANSMISSION

Enables or disables the transmission of log events to the external Syslog

 

server.

HOST IP

Lists the IP address of the external server that is running the Syslog host dae-

ADDRESS

mon.

HOST FACILITY

Specifies the facility destination of log events. Facilities are

 

located on the host and are managed by the Syslog host

 

daemon running on either a UNIX machine or a PC.

REAL TIME CLOCK Write security: 3; Read security: 5

Provides access to the following two options that you can review and edit:

CURRENT TIME/ Displays the current date and time, including sec-

DATEonds. To edit this field, enter the time in 24-hour format (such as 23:13:47 for 11 pm, 13 minutes and

47seconds), and enter the date in mm-dd-yyyy format (for example,

11-08-1999).

AUTO DAYLIGHT

When enabled, automatically updates the time and date when Daylight Sav-

SAVINGS

ings Time starts and, also, when Standard Time starts.

6-14

ATLAS 550 User Manual

61200305L1-1