Agilent Technologies S GSM, 8922M manual GSM/DCS1800/P

Models: 8922M S GSM

1 381
Download 381 pages 1024 b
Page 134
Image 134

Screens

Cell Control - Active Cell

4.

Bit Error

This field displays the bit error or fast bit error measurements screen depending on

 

 

which mode has been set in these screens.

 

 

See Also

Screens: Bit Error or Fast Bit Error

5.

Call Status

This field displays the status of the communication between the mobile phone and

 

 

the Agilent 8922M/S. For the active cell, the states are:

Inactive

Proceeding

Alerting

Connected

6.Channel (Base This field selects which channel the Agilent 8922M/S transmits the Broadcast

Station)

Channel (BCCH) information. If this is changed during a call, the call will be

 

deactivated.

 

7. CW Meas

This field displays the CW measurements screen.

8. dBm

This field displays the units of the Peak Power measurement.

 

See Also

Keys: ON/OFF, HI LIMIT, LO LIMIT, REF SET, AVG,

 

 

UNITS, METER

9. GSM900/E-

This field selects the type of mobile that is to be tested.

GSM/DCS1800/P

Choices

GSM 900

CS1900

 

E-GSM

 

 

 

 

DCS 1800

 

 

PCS 1900

10. Out RF SP

This field displays the output RF spectrum measurements screen.

11.Peak Power This field displays the measured peak carrier power.

NOTE

The measurement display will not update if there is no signal to measure. This

 

includes the case where the expected input level has been set too high.

 

 

12. Phase/Frq

This field displays the phase and frequency measurements screen.

4-28