Screens

Fast Bit Error

Fast Bit Error

1.Amplitude (Base This field changes the RF generator amplitude. It is a duplicate of the RF generator’s

Station)

Amplitude field on the RF Generator/RF Analyzer screen.

 

See Also

Screens: RF Generator/RF Analyzer (RF Generator).

2. BE Ratio

This field selects how bit errors will be displayed.

 

Choices

BE Count displays the total number of bit errors.

 

 

BE Ratio calculates and displays the ratio of bit errors counted to

 

 

the total number of bits measured (depends on measurement type).

3.BE Ratio/Count This field displays the result of the bit error ratio after all the bits have been tested.

4.Data Format This field allows the user to select the data format for the BER measurements.

Choices

RAND SPEECH this uses random speech frames and enables the

 

mobile to calculate Rx Quality correctly.

 

RAND BURSTS this generates random bursts, but the mobile is

 

unable to calculate Rx Quality.

4-56