APPENDIX A

Setting Up the Agilent Technologies 8922M

 

Setting Up the Agilent Technologies 8922M

Camp On

Firstly, the Mobile Station should be "camped" on to the Agilent 8922M. That is the

 

MCC, MNC, LAC should all be correct, and any adjustments to power level made as

 

appropriate to the Mobile under test.

 

For more details on how to get "camped" on refer to "Making a Call From the

 

Agilent 8922M/S to the Mobile Phone", Chapter 2, Agilent 8922M/S GSM Test Set

 

User’s Guide.

Set up Logging Set up the logging conditions to the Protocol Port using the logging screen. The

Screenlogging screen gives you control over the Protocol Interface port on the rear panel. The screen is selected by highlighting More and selecting LOGGING. Then from highlighting the field below Pass Filter, one of the following logging conditions are available;

a)NetwkOnly

b)+DataLink

c)+Service

For a full explanation of these options refer to "Additional Information", page A-11.

Set Service To enable protocol logging, the correct service latch must be set.

Latch

To set the correct service latch from the Cell Control screen select CONFIG. Then select SERVICE and then Latch. From this field choose g_log_configuration and ensure the Value is set to 0.

Return to the Logging Screen.