APPENDIX A

Setting Up the HP/Agilent 37900D

From the HP/Agilent 37900D start-up screen highlight MANUAL MODE. Select t until CONFIGURATION is highlighted then hit Retur .

PERSONALITY

APPLICATIONS MANUAL MODE

HELP

Then from the CONFIGURATION MODE menu, press ’M’ and select the slot to be modified.

Set up the parameters for Port A as shown below

 

 

 

 

 

RS-449/422, RS-232

 

SLP

 

 

 

 

Port A

Port B

Slot

Card

+---------------------------

+-------------------------

+

3

RS449/422,RS232

 

RS449 DCE

I’FACE HIGH M

RS232 DTE

I'FACE HIGH M

2

Slave Signal

 

 

1

 

 

No Card

 

No Card

0

 

 

No Card

 

No Card

 

 

 

+---------------------------

+-------------------------

+

------------------------------------------------------------------------------

 

{{CURRENT SETTING}}

 

 

I - Interface

>> RS-449/442

>> RS-449/442

S * connection Setup

>> MONITOR

>> MONITOR

 

D - DCE/DTE

>> DCE

>> DTE

 

C - Clock source

>> I/FACE HIGH

>> I/FACE HIGH

T - TXD Timing source

>> TX CLOCK DTE SOURCED

>> TX CLOCK DCE SOURCED

P - mark Polarity

>> NORMAL

>> NORMAL

 

O - modify Other port

A - Auto-configure other

port

Q - Quit

Enter menu option:

 

 

 

For Example, to change the Interface Setting;

Press ’I’

A new menu is shown listing the available options. When you have selected the required option, you are returned to the above menu.

Select Quit (’Q’ from keyboard) twice.

Select Yes (’Y’ from keyboard) to return to start-up screen.

Refer to the HP/Agilent 37900D Monitor Guide for detailed information on using the HP/Agilent 37900D Signaling Test Set.

A-7