Verifying Performance

Agilent Technologies 8922M/S Specifications

FM Demodulation Output (Agilent 8922M only)

Range

RF In/Out

Aux RF In

Sensitivity

Input Frequency Setting Error

Input Level Setting Error

Supplemental Characteristics

3 dB Bandwidth

Output Impedance

DC Offset

6 to +41 dBm 36 to +20 dBm

20μV/Hz ±5% (into an open circuit)

±50 kHz, with 100 kHz pk deviation

±3 dB

DC to 270 kHz

600Ω

5 mV

Pulse Demodulation Output (Agilent 8922M only)

Range

RF In/Out

Aux RF In

Input Frequency Setting Error Input Level Setting Error Rise Time (10 to 90%)

Fall Time (90 to 10%) Supplemental Characteristics:

Output Impedance

Output Level

6 to +41 dBm 36 to +20 dBm

±50 kHz

±3 dB 2.5 μs 2.5 μs

600 Ω, DC Coupled

2 Vpk into an open circuit

3-22

Page 97
Image 97