Verifying Performance

Agilent Technologies 8922M/S Specifications

 

 

Agilent Technologies 8922M/S Specifications

 

 

 

 

 

NOTE:

If you have the Agilent 8922M/S Option 010 Multi-Band Test System, refer to the

 

 

appropriate Agilent 8922 Multi-Band User’s Guide for more information on

 

 

specifications relevant to dual band testing.

 

 

 

 

 

GSM900 and

 

 

 

E-GSM900

 

 

 

Functionality

 

 

 

 

 

 

 

 

Bit/Frame Error Rate Measurements:

Class 1a, 1b, and Class II bits in both raw and residual form.

 

 

 

 

Also Burst-by-Burst Bit Error Measurement

 

 

MS Power Output Level Control:

0 to 19 with RF analyzer auto adjust

 

 

Broadcast Channel Capability:

BCCH + CCCH or BCCH + CCCH + SDCCH/4

 

 

Control Channels (SDCCH, FACCH,

BCCH + CCCH, BCCH + CCCH + SDCCH/4, SDCCH/8

 

 

SACCH)

 

(non-hopped), SACCH/FACCH

 

 

Call Control Capabilities

BS originated call (FS/EFS), MS originated call (FS/EFS),

 

 

 

 

MS camp on, BS call disconnect, MS call disconnect

 

 

Traffic Channels

 

TCH (FS/EFS)

 

 

HSCSD

 

2x1 and 2x2, 9.6 kbs and 14.4 kbs

 

 

Timing

 

Auto, manual, uplink-downlink, offset measurement

 

 

Hopping

 

Two independent, user definable MA tables with offsets

 

 

Speech Encoding/Decoding

Full rate speech

 

 

Speech Echo Mode

User selectable delay 0 to 5 sec on Agilent 8922M, fixed

 

 

 

 

delay on Agilent 8922S

 

 

Measurement Coordination

Flexible control of burst type, ARFCN, and timeslot.

 

 

SACCH MEAS Result

RXLEV, RXQUAL, and timing advance.

 

 

SMS Cell Broadcast

Two predefined messages with user definable attributes

 

 

 

 

(code, update number, language and identifier).

 

 

 

 

 

 

RF Generator

Frequency

 

 

Specifications

 

 

 

Range

Resolution

Accuracy

Stability

10 MHz to 1 GHz

1 Hz

Reference accuracy ± 0.5 Hz

Same as reference

3-14