4. Aux BCCH

NOTE

NOTE

5.BA

6.BCC

7.CA

Screens

Cell Configuration - E-GSM, DCS 1800, PCS 1900

This field allows selection of data and clock outputs.

This is not featured in the Agilent 8922S.

Choices

Off causes the front-panel MODULATION IN/OUT DATA and

 

CLOCK connectors to be inputs.

 

Adjacent causes data and clock signals to be output on the front-

 

panel MODULATION IN/OUT DATA and CLOCK connectors.

 

These signals can be connected to a 0.3 GMSK generator

 

(HP/Agilent 8657A/B Option 022.) A mobile station should be

 

able to camp on to the Aux BCCH.

 

The BCC (Base Station Colour Code) is displayed in this field and

 

has a number plus 1 modulo 4 relationship with Serv Cell BCC.

The data output includes a midamble, which will result in discrete sidebands. If random data is desired, use an HP/Agilent 8904A Option 001 or 002 to generate random data and clock signals to the 0.3 GMSK generator.

See Also

Connectors and Timing Diagrams: CLOCK (MODULATION)

 

Connectors and Timing Diagrams: IN/OUT DATA

 

(MODULATION)

This field is list defining which ARFCNs are in the base station allocation. The serving cell ARFCN does not have to be included in this list.

This field sets the base-station color-code portion of the BSIC (base station identity code for the serving cell).

Range

0 through 7

This field is a list defining which ARFCNs are in the cell allocation table. It is used to define the ARFCNs used in the TCH hop sequence.

4-24

Page 130
Image 130
Agilent Technologies S GSM, 8922M manual BCC Base Station Colour Code is displayed in this field