Port

 

 

 

 

 

set port remote-fault-detect

 

Command Mode

Global Configuration.

 

Description

Enables or disables remote fault detections for gigabit ports. Remote fault

 

 

detection makes it possible for a Gigabit port at one end of a link to signal

 

 

status to the other end of the link, even if it does not have an operational

 

 

receive link.

 

 

 

* Note: Auto-negotiation and remote fault detection can not be enabled

 

 

at the same time. Auto-negotiation must be disabled to enable

 

 

remote fault detection. When auto-negotiation is enabled,

 

 

remote fault detection is automatically disabled.

 

Syntax

 

 

 

 

 

 

 

 

To Enable:

set port remote-fault-detect {<mod-num> <mod-port-

 

 

 

range>}[...,{<mod-num> <mod-port-range>}] enable

 

 

 

 

 

 

To

set port remote-fault-detect {<mod-num> <mod-port-

 

 

Disable:

range>}[...,{<mod-num> <mod-port-range>}] disable

 

 

 

 

 

 

Table 21-33. Parameters, Keywords, Arguments

 

 

 

 

Name

Definition

 

 

 

 

<mod-num>

Specifies the number of the module where the ability to

 

 

detect remote link errors for each gigabit port on the

 

 

module is to be set.

 

 

 

 

<mod-port-range>

Specifies a port or a range of gigabit ports whose ability to

 

 

detect remote link errors are enabled or disabled.

 

 

 

Sample Output

The following example enables remote fault detection in gigabit ports 1 and

 

2 on the module in slot 3 of an Avaya Multiservice switch.

 

(configure)# set port remote-fault-detect 3/1,3/2 enable

 

Port remote fault detection enable set: 3/1,3/2

Systems

P550R, P580, P880, and P882.

Document No. 10-300090, Issue 1

21-39

Page 471
Image 471
Avaya 106760804 manual Set port remote-fault-detect, To Enable