Chapter 31

set temperature (warning)

Command Mode

Global Configuration.

Description

Sets the warning temperature (in Celsius) for a specific component of the

 

switch. The default values are listed in Table 31-3.

 

Table 31-3. Default Warning Temperatures

 

 

 

 

 

 

 

Component

Upper

Lower

Low Limit

 

 

Warning

Warning

 

 

 

 

 

 

 

CPU Sensor

85°

 

 

 

 

 

 

All others

60°

 

 

 

 

 

Syntax

set temperature {supervisor-slot backplane-sensor cpu-sensor probe}

 

warning {upper lower low-limit} <temperature>

 

Table 31-4. Parameters, Keywords, Arguments

Name

Definition

 

 

{supervisor-slot

Indicates which component of the switch you are setting

backplane-sensor

the temperature for.

cpu-sensor probe}

Note: After you change the temperature settings for the

 

 

active supervisor, you must synchronize the active

 

and standby supervisors to copy the temperature

 

settings to the standby supervisor.

 

 

warning

Required parameter indicating that a warning limit is

 

being modified.

 

 

 

1 of 2

 

 

31-4

Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

Page 694
Image 694
Avaya 106760804 manual Set temperature warning, Default Warning Temperatures, Component Upper Lower Low Limit