Chapter 21
21-20 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set port internal-error-shutdown
Command Mode Global Configuration.
Description Sets switch ports to shutdown if their rate of internal errors exceeds the
threshold setting. To set the threshold, use the set-internal-error-threshold
command. For information on this and other IEDR commands, see
Chapter 18, “NEDR and IEDR.”
Syntax
Sample Output The following example enables IEDR on all ports on the module in slot 3.
(configure)# set port internal-error-shutdown 3 enable
Systems P550R, P580, P880, and P882.
To En ab le: set port internal-error-shutdown {<mod-num> | <mod-
swport-spec> | all-ports} enable
To Di sa b le : set port internal-error-shutdown {{<mod-num> | <mod-
swport-spec>}| all-ports} disable
Table 21-18. Parameters, Keywords, Argument
Name Definition
{<mod-num> | <mod-
swport-spec>} The slot number of the module, and, either port
number, or range of port numbers. Enter the port
ranges in the format Px-Py. For example:
To specify port 1 on the module in slot 3, enter
3/1.
To specify ports 1 through 5 on the module in
slot 3, enter 3/1-5.
all-ports Enables or disables IEDR on all ports on all modules in
the switch.