System

 

set utilization threshold-event

Command Mode

Global Configuration.

Description

Enables event logging for utilization monitoring of the CPU or forwarding

 

engines. When event logging is enabled, the switch generates an event if the

 

high-utilization threshold is exceeded.

 

The default setting for event logging of utilization monitoring is disabled. If

 

you enable event logging for utilization monitoring but do not specify a

 

utilization threshold, the switch logs an event if the CPU utilization or

 

forwarding engine utilization exceeds 95 percent. To change the utilization

 

threshold, use the set utilization high-thresholdcommand.

Syntax

To Enable:

set utilization threshold-event {cpu forwarding-engine}

 

 

To Disable:

clear utilization threshold-event {cpu forwarding-

 

engine}

 

 

 

Table 30-37. Keywords, Arguments, and Options

 

 

 

 

Name

Definition

 

 

 

 

cpu

Enables event logging for CPU utilization.

 

 

 

 

forwarding-engine

Enables event logging for utilization of 80-

 

 

series forwarding engines.

 

 

 

Systems

P580 and P882.

 

Document No. 10-300090, Issue 1

30-57

Page 673
Image 673
Avaya 106760804 manual Set utilization threshold-event, Keywords, Arguments, and Options