Chapter 21

set port intrusion-trap-timer

Command Mode

Global Configuration.

Description

Sets the time interval at which intrusion traps are generated. The default

 

setting for the intrusion trap timer is 1800 seconds (30 minutes). The valid

 

range for the timer is 60 to 1800 seconds.

Syntax

set port intrusion-trap-timer {<mod-num> <mod-swport-range>}

 

[...,{<mod-num> <mod-swport-range>}]<intrusion-trap-timer-value>

 

Table 21-20. Parameters, Keywords, Arguments

 

 

 

 

Name

Definition

 

 

 

 

<mod-num>

Specifies the number of the module.

 

 

 

 

<mod-swport-

Specifies a range of switch ports.

 

range>

 

 

 

 

 

<intrusion-trap-

Time interval at which intrusion traps are generated.

 

timer-value>

The default setting for the intrusion trap timer is 1800

 

 

 

 

seconds (30 minutes). The valid range for the timer is 60 to

 

 

1800 seconds.

 

 

 

Systems

P550R, P580, P880, and P882.

21-22

Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1