Temperatures

 

Table 31-4. Parameters, Keywords, Arguments

 

 

 

 

Name

Definition

 

 

 

 

{upper lower

Indicates warning being changed.

 

low-limit}

Upper warning:

 

 

 

 

• Backplane is 5 to 65 degrees

 

 

• CPU is 5 to 100 degrees

 

 

• Supervisor Module is 5 to 65 degrees.

 

 

Lower warning:

 

 

• Backplane is -128 to 5 degrees

 

 

• CPU is degrees 0 to 100

 

 

• Supervisor Module is 0 to 65 degrees.

 

 

Low- limit:

 

 

• Backplane is -128 to +5 degrees

 

 

• CPU is -128 to +100 degrees

 

 

• Supervisor Module is -128 to +65 degrees.

 

 

 

 

<temperature>

Temperature in degrees Celsius for the warning.

 

 

 

 

 

2 of 2

 

 

 

Sample Output

The following example sets the backplane-sensor upper warning

 

temperature to 44° (Celsius).

 

(configure)# set temperature backplane-sensor warning upper 44

Systems

P550R, P580, P880, and P882.

Document No. 10-300090, Issue 1

31-5

Page 695
Image 695
Avaya 106760804 manual Following example sets the backplane-sensor upper warning