_K==oÉãçíÉ=`çåíêçä
•
•
Remote Commands
List Format: Each input type has a different list of valid sample modes. ISMP
List Response: 0:"OverSample" 1:"1:1"
fpvk`
•
•
•
•
•
•
•
Description: Input Sync Type Adjust. This command is only valid for analog input types.
Command Format: ISYNC
Parameters:
Query Response: ISYNC
List Format: ISYNC
List Response: 0:"AUTO"
1:"H/V"
2:"CSYNC"
3:"SOG"
fqvmb
•
•
•
•
•
•
•
Description: Input Type Adjust. This command is only adjustable for the analog inputs. Other inputs will provide query information only.
Command Format: ITYPE
Parameters:
Query Response: ITYPE
List Format: Each input type has a different list of valid input types. ITYPE
List Response: 1:"RGB"
2:"Y/C"
3:"CVBS"
4:"SDI"
5:"DVI"
6:"YPbPr"
|
| 145 |
|