3. Installation

Power Installation

mçïÉê=`çêÇLiáåÉ=sçäí~ÖÉ=pÉäÉÅíáçå

DCS-200 is rated to operate with the following specifications:

Input Power: 100-240 VAC, 50-60 Hz

Power Consumption: 240 watts maximum

DCS-200 performs line voltage selection automatically, and no user controls are required. The AC power cords must be accessible so that they can be removed during field servicing.

Warning

When the DCS-200 is used in the 230-volt mode, a UL listed line cord rated for 250 volts at 15 amps must be used and must conform to IEC-227 and IEC-245 standards. This cord will be fitted with a tandem prong-type plug.

The rear panel ON/OFF switch does not disconnect the unit from input AC power. To facilitate disconnection of AC power, the power cord must be connected to an accessible outlet near the unit.

Building Branch Circuit Protection: For 115 V use 20 A, for 230 V use 8 A.

Figure 3-1.Tandem Prong-type Plug

Avertissement

La choix de la ligne de voltage se réalise automatiquement par le DCS-200 Transformateur Graphique. On n'a pas besoin du controller usager pour la choix de la ligne de voltage.

Warnung

Das DCS-200 gerät mu beim Anschlu an 240V ~ mit einer vom VDE auf 250V/10A geprüften Netzleitung mit einem Schukostecker ausgestattet sein.