_K==oÉãçíÉ=`çåíêçä

Remote Commands

10:"800x600 @50" 11:"800x600 @56" 12:"800x600 @59.94" 13:"800x600 @60" 14:"800x600 @72" 15:"800x600 @75" 16:"800x600 @85"

lpo`

Description: Selects the input source for the preview output (preview or program).

Command Format: OSRC -s (source)

Parameters: -s (source): 0-preview, 1-program

Query Format: OSRC -?

Query Response: OSRC -s (source)

List Format: OSRC --list

List Response: 0:"PREVIEW" 1:"PROGRAM"

lpvk`=

Description: Output Sync Type Adjust.

Command Format: OSYNC -o (output) -s (sync) Parameters:

-o (output): 1 - DVI, 2 - Analog, 3 - Preview DVI, 4 - Preview Analog

-s (sync): 1 = +H+V, 2 = +H-V, 3 = -H+V, 4 = -H-V, 5=CSync for analog

only (Defaults: DVI : +H+V, analog: -H-V) Query Format: OSYNC -o (output) -?

Query Response: OSYNC -o (output) -s(sync) --min 1 --max 4 (max returned for analog is 5)

List Format: OSYNC -o (output) --list

List Response: 1:"+H+V"

2:"+H-V"

3:"-H+V"

4:"-H-V"

5.”CSync” (returned for analog only)

lqmj=

Description: Output Test Pattern Mode

Command Format: OTPM -o (output) - m (mode)

DCS-200 • User’s Guide

 

149

 

Page 149
Image 149
Barco DCS-200 manual Lpo`, Lpvk`=, Lqmj=