Remote Commands

The SERIAL query will return only one option parameter at a time. If no option is specified, an error code will be returned.

Query Response: SERIAL -b (baud) --min 0 -- max 3

SERIAL -p (parity/etc) --min 0 -max 4 SERIAL -h (handshaking) --min 0 -max 1

qbjm

Description: Query only command for the temperature of the unit.

Query Format: TEMP -?

Query Response: TEMP -c (celsius) -f (fahrenheit)

qokqfjb=

sbo

Description: Set transition time

Command Format: TRNTIME -s (seconds)

Parameters: -s (seconds): 1.5 - 5.0 (default: 1.5)

Query Format: TRNTIME -?

Query Response: TRNTIME -s (seconds) --min 1.5 -- max 5

Description: Display Version info

Command Format: VER

Parameters: N/A

Query Format: N/A

Query Response: N/A

sca_oq=

Description: Set VFD brightness

Command Format: VFDBRT -b (brightness) -f

Parameters:

-b (brightness): 1 - 16 (default: 10)

-f: Command from front panel Query Format: VFDBRT -?

Query Response: VFDBRT -b (brightness) --min 1 -- max 16

hÉó=`çãã~åÇë

ihbv=

Description: Luminance Key definition

Command Format: LKEY -m (mode) -s (source) -c (clip) -g (gain) -o (opacity) -h (hoffset) -v (v offset)

DCS-200 • User’s Guide

 

155

 