Clearing a Power-On or Setup Password
To disable the
1.Turn off the workstation. Disconnect the power cord from the grounded AC outlet and from the power connector on the rear of the workstation.
2.Remove the following components:
❏side access panel
❏I/O bracket assembly (expansion board assembly)
3.On SW1, move Switch 1 to the ON position.
SW1 |
on |
1 2 3 4 5 6 |
Figure 5-1. Locating the default SW1 switch
IMPORTANT: Switch 1 has a default setting of OFF. When the switch is OFF, your system is
4.Reassemble the workstation and reconnect the power cord to the grounded AC outlet and to the power connector on the rear of the workstation.
IMPORTANT: You must replace the I/O bracket assembly before you restart the workstation. If the assembly is not properly seated, the workstation will not start.
5.Restart the workstation.
6.Turn off the workstation once more. Disconnect the power cord from the grounded AC outlet and from the power connector on the rear of the workstation.
7.Remove the side access panel and the I/O bracket assembly to access SW1 on the system board.
Compaq Professional Workstation AP500 Maintenance and Service Guide