Compaq AP500 manual 4Diagnostic Tools, Post Messages, Message Beeps Probable Cause

Models: AP500

1 179
Download 179 pages 479 b
Page 80
Image 80

4-4Diagnostic Tools

POST Messages Continued

Message

Beeps*

Probable Cause

 

 

 

 

 

206-Secondary cache

None

Cache memory controller or

controller failure

 

 

RAM failure

 

 

 

207-ECC Corrected Single

2S

A memory error on one of the

Bit Errors in DIMM Pair(s)

 

 

installed DIMMs has been

 

 

 

detected and corrected with the

 

 

 

system’s ECC logic. The

 

 

 

workstation will continue to

 

 

 

operate correctly with this error.

 

 

 

 

 

Recommended Action

Run the Computer Checkup and Diagnostics utilities.

Run Diagnostics to get more information.

210-Invalid Memory

None

Too much memory installed in

Remove DIMM from socket.

Configuration Detected.

 

system

 

 

Maximum of 1 Gbytes of

 

 

 

 

Memory Supported. System

 

 

 

 

Halted

 

 

 

 

 

 

 

 

212-Failed Processor

1L

Failed processor (X is 0 or 1)

Replace the processor and/or the

 

 

 

Processor Power Module.

 

 

 

 

301-Keyboard Error

None

Keyboard failure

Verify that you do not have a key stuck

 

 

 

or something on the keyboard.

 

 

 

Ensure that the keyboard is plugged in.

 

 

 

Replace the keyboard.

 

 

 

 

303-Keyboard Controller

None

I/O keyboard controller

1. Reconnect keyboard with computer

Error

 

 

 

turned off.

 

 

 

2.

Replace the system board.

 

 

 

 

 

304-Keyboard or System

None

Keyboard failure

1.

Replace the keyboard.

Unit Error

 

 

2.

Replace the system board.

 

 

 

 

 

 

 

40X-Parallel Port X Address

2S

Both external and internal ports

Run Computer Setup or Windows NT

Assignment Conflict

 

are assigned to parallel port X.

utilities.

 

 

 

 

402-Monochrome Adapter

1L, 2S

Monochrome display controller

Replace the monochrome display

Failure

 

 

controller.

 

 

 

 

404-Parallel Port Address

2S

Both external and internal ports

Run Computer Setup or Windows NT

Conflict Detected

 

are assigned to parallel port X.

utilities.

 

 

 

 

501-Display Adapter Failure

1L, 2S

Graphics display controller

Replace the graphics controller.

 

 

 

 

 

601-Diskette Controller Error

None

Diskette controller circuitry

1.

Run Computer Setup.

 

 

 

2.

Check and/or replace cables.

 

 

 

3.

Replace diskette drive.

 

 

 

4.

Replace the system board.

Continued

Page 80
Image 80
Compaq AP500 manual 4Diagnostic Tools, Post Messages, Message Beeps Probable Cause