Compaq AP500 manual Diskette Drive Type Mismatch in drive type

Models: AP500

1 179
Download 179 pages 479 b
Page 81
Image 81

 

 

 

 

 

4-5

POST Messages Continued

 

 

 

 

 

 

 

 

Message

Beeps*

Probable Cause

Recommended Action

 

 

 

 

 

 

 

 

 

605-Diskette Drive Type

2S

Mismatch in drive type

 

 

Run Computer Setup or Windows NT

Error

 

 

 

 

 

 

utilities.

 

 

 

 

 

 

611-Primary Floppy Port

2S

Configuration error

 

 

Run Computer Setup or Windows NT

Address Assignment Conflict

 

 

 

 

 

 

utilities.

 

 

 

 

 

 

1151-System Board COM Port

2S

Both external and internal serial

 

 

Run Computer Setup or Windows NT

1 Address Assignment Conflict

 

 

ports are assigned to COM1

 

 

utilities.

 

 

 

 

 

 

1152-System Board COM Port

2S

Both external and internal serial

 

 

Run Computer Setup or Windows NT

2 Address Assignment Conflict

 

 

ports are assigned to COM2

 

 

utilities.

 

 

 

 

 

 

1155-COM Port Address

2S

COM port address conflict

 

 

Run Computer Setup or Windows NT

Assignment Conflict

 

 

 

 

 

 

utilities.

 

 

 

 

 

 

1610-Temperature Violation

None

The system is too hot.

 

 

Turn off the workstation and let it cool off.

Detected

 

 

 

 

 

 

If the condition persists, run Diagnostics to

 

 

 

 

 

 

 

get more information.

 

 

 

 

 

 

1611-Fan Failure Detected

None

The fan is not operating properly.

 

 

Run Diagnostics to get more information.

 

 

 

 

 

 

 

Replace the fan.

 

 

 

 

 

 

 

 

 

1720-IntelliSafe Hard Drive

None

Detects Imminent Failure

 

 

 

1720-SMART Hard Drive

None

Detects Imminent Failure

 

 

 

1771-Primary Disk Port

2S

Address Assignment Conflict

 

 

 

1772-Secondary Disk Port

2S

Address Assignment Conflict

 

 

 

1780-Disk 0 Failure

None

 

 

1781-Disk 1 Failure

None

 

 

1782-Disk Controller Failure

None

 

 

1790-Disk 0 Failure

None

(Secondary)

 

 

 

1791-Disk 1 Failure

None

(Secondary)

 

 

 

1792-Secondary Disk

None

Controller Failure

 

 

 

IDE hard drive(s)

SCSI hard drive(s)

Internal and external IDE hard drive controllers are both assigned to the primary address.

IDE Configuration

IDE hard drive failure

IDE hard drive failure

IDE configuration failure

IDE hard drive failure

IDE hard drive failure

IDE circuitry failure

Back up contents and replace hard drive.

Back up contents and replace hard drive.

Run Computer Setup or Windows NT utilities.

Run Computer Setup.

Run Computer Setup.

Run Computer Setup.

Run Computer Setup.

Run Computer Setup.

Run Computer Setup.

Run Computer Setup.

Continued

Compaq Professional Workstation AP500 Maintenance and Service Guide

Page 81
Image 81
Compaq AP500 manual Diskette Drive Type Mismatch in drive type